Lower Emissions
Not sure which solution fits your needs? Contact Your Rep
Overview
Cleaver-Brooks works with customers to tailor solutions that help them decrease emission levels to both be more environmentally friendly and meet ever stringent guidelines. In some cases, that means replacing the boiler system. In other cases, Cleaver-Brooks can retrofit products to help a company meet its emission goals.
Explore our product selector by using the tabs to view the options appropriate for your needs.
New Boiler
Whether you choose a Firetube or Watertube, large or small capacity, all Cleaver-Brooks boilers are designed to be as efficient as possible and provide the lowest emissions.
| CBEX Elite |
CBND Series |
Electrode Boiler |
ClearFire-LC |
View Full Product Details
|
View Full Product Details
|
View Full Product Details
|
View Full Product Details
|
Highest Efficiency
- Steam and hot water
- 100 to 1,200 HP
- Natural gas, #2 light oil or combination
- 50 to 250+ psig on steam, 30 to 125 psig on hot water
- Available to <5 ppm NOx
|
Steam-ready
- Saturated steam
- 10,000 to 225,000 lb/hr
- Natural gas, #2 oil
- Design pressure up to 1,500 psig
- Available to less than 7 ppm NOx, Ultra-Low CO
|
Model: CEJS
- High-voltage steam boiler
- 4.16-25 kV – up to 188,000 lb/hr
- 100-500 psi
- No local emissions
- Fast response time
|
Large Capacity, Full Condensing
- Full condensing hydronic boiler
- 4,000 to 12,000 MBTU/hr
- Ultra-low emissions
- Up to 98% efficiency
- Offers 5:1 turndown
|
Upgrade Your Burner
Every Cleaver-Brooks burner is designed and built to increase your boiler’s efficiency and decrease emissions.
| ProFire®-XL Series |
ProFire®-D Series |
ProFire®-MTH Series |
NATCOM Retrofit Burner |
View Full Product Details
|
View Full Product Details
|
View Full Product Details
|
View Full Product Details
|
Large, Forced Draft Burner
- 37.8 to 92.4 MMBTU input range
- 900 to 2,200 HP
- Gas, oil, combination
- Available to <9 ppm NOx
|
Forced Draft Burner
- 4.2 to 42.0 MMBTU input range
- 100 to 1,000 HP
- Gas and #2-#6 oil, combination, alt. fuels
- Available to < 9 ppm NOx
|
Forced Draft Burner
- 2.5 to 16.0 MMBTU
- 60 to 380 HP
- Natural gas or propane
- Low NOx achieved without FGR
|
Retrofit Systems
- Steam and hot water applications
- 20 to 400 MMBTU
- Natural gas, #2 and #6 oil, combination, other
- Available to <9 ppm NOx, <50 ppm CO
- Saves fuel and lowers emissions
|
Controls
Ensure your system runs at peak efficiency with our integrated boiler room controls. Regardless of your boiler system, there's a control that will complement it.
| Hawk 1000 |
Hawk 4000 |
View Full Product Details
|
View Full Product Details
|
Integrated Boiler Room Control
- Saves fuel
- Keeps your boiler operating at peak performance
- 4” color touch screen
- Intuitive interface
- New or retrofit boiler applications
- Ideal for commercial or light industrial applications
|
Advanced Boiler Room Control
- Saves fuel
- Optional oxygen trim and variable-speed drive
- Control economizers and other equipment
- 7” color touch-screen interface, PLC-based
- Custom programming available
- uL Listed
|
Water Systems
Increase the safety, reliability and life of your boiler with water treatment and feed and recovery options.
| SprayMaster Signature Deaerator |
Surge Tank |
Boiler Feed System |
Water Softeners |
View Full Product Details
|
View Full Product Details
|
View Full Product Details
|
View Full Product Details
|
Model SMP
- 7,000-100,000 Lbs/hr.
- Steam and Hot Water applications
|
Model SRG
- 300-3,000 Gals.
- Steam and Hot Water applications
|
Model BFS
- Atmospheric pressure
- Steam and Hot Water applications
- Up to 1,000 gallons
|
Models: SMR & FMR, FSE & SSE, CRS
- Steam and hot water applications
- Sized from 20,000 to 1,500,000 grains exchange capacity
- Flow rates from 2 to 450 gpm
- Tanks of FRP plastic or steel
- Compatible with all boiler applications
|
Parts & Service
Turnkey conversions and comprehensive upgrade and retrofit capabilities from our world-class engineering staff make it easy to lower emissions or bring any age system back to the manufacturer’s original specifications. Whatever advantage or benefit you may need, Cleaver-Brooks has the solution and dedicated aftermarket team to help you engineer and implement it.
Our proprietary BOOSTSM report can determine the exact upgrades and accessories your existing boiler system needs to increase its efficiency to its absolute maximum and decrease emissions. By installing the right burners, controls and heat recovery equipment, you can realize substantial savings immediately, and savings of hundreds of thousands of dollars over the life of the boiler. And our financial report details the cost savings in real numbers, so you can prove it’s the right thing to do.
Complete our information request form
with your system’s details and a member of our Parts and Service team will help you develop a custom solution, or contact your local rep today to start developing a program that’s right for you.